Page iii: Full general Information
GENERAL Data This manual provides information necessary to operate the BONSAI VELOCITY ® pneumatic conserver with built-in regulator� The BONSAI VELOCITY conserver can exist used with whatever CGA 870 post-valve cylinder ® [see Fig� A] at domicile or away from home to provide your specific oxygen requirements� Statements in this manual preceded past the post-obit words are of special significance: Alert! Indicates in that location is a possibility of injury... -
Page 4: Of import Safe Rules And Precautions
Important SAFETY RULES & PRECAUTIONS Warning! • Read and sympathise this manual earlier operating your BONSAI VELOCITY ® pneumatic oxygen conserver� • This device is non intended for use during slumber or by patients who: - Exhale more than than xl breaths per minute, - Consistently fail to trigger equipment (due east�k�, mouth breathers)� Smoking nigh oxygen equipment is strictly prohibited. Keep cigarettes, matches, called-for tobacco and open flames, such as lighted candles, away from the area where the system is beingness stored or operated�... - Page 5 Important SAFETY RULES & PRECAUTIONS CAUTION: • Federal (USA) law restricts this device to sale by or on the order of a physician. • Prevent water or other liquid substances from inbound the unit of measurement. • Forbid dust or any small particles from entering the unit of measurement. • Practise not expose the unit of measurement to extreme temperatures. • E'er maintain a backup supply of oxygen. • Exercise non use humidifier bottles. • Do non use if leaking or damaged. • Refer repairs to authorized service personnel. NOTE: Oxygen supplied by this equipment is supplemental only and is not intended for life back up applications. The BONSAI VELOCITY conserver should not be used to supply anything ®...
-
Page 6: Introduction
INTRODUCTION The BONSAI VELOCITY pneumatic oxygen conserver includes a combination of a low- ® pressure regulator and an oxygen conserver� It is designed for apply with a cylinder as an convalescent oxygen system and is capable of delivering a precise amount of supplemental oxygen at the optimal point in the breathing cycle�... -
Page vii: Description Of Parts And Controls
Clarification OF PARTS & CONTROLS • Cylinder Adjustment Knob: This is used to attach the Cylinder unit of measurement to any CGA 870 post-valve cylinder� Adjustment Knob • Oxygen Pressure level Gauge : Enables the user to monitor the contents of the compressed oxygen cylinder and is protected past a rubber guard�... - Folio 8 DESCRIPTION OF PARTS & CONTROLS • CF Setting: Enables the user to switch from pulse mode (oxygen delivery on demand) to continuous flow manner in the unlikely event of unit malfunction. The CF setting is designed for emergency utilize only [see Fig C]� [There are two CF Settings; 2 LPM and 4 LPM] NOTE: Remember that in continuous flow way, the oxygen volition be consumed at a much faster rate.
-
Page 9: Associates And Apply
ASSEMBLY AND Employ • Make certain that your hands are gratis of oil, grease, and other contaminants. • Audit the unit to ensure that it has the advisable viton (or equivalent) seal washer (gasket), in practiced working condition, attached to the inlet nozzle. • Secure the cylinder in an upright position. • Inspect the valve of the cylinder and the BONSAI VELOCITY conserver to ensure they ® are free of contaminants� If any indication of damage or contagion is detected, Do NOT use the equipment and contact your Dwelling Intendance Provider� Warning! Use ONLY a manufacturer-specified seal washer (gasket). -
Page 10: Installing The Organization
ASSEMBLY AND Utilize INSTALLING THE Organization: Pace one: Loosen the cylinder adjustment knob. Stride 2: Lower the BONSAI VELOCITY conserver ® over whatever post-valve cylinder with the alignment pins toward the holes on the cylinder cervix [meet Fig. F]. Step 3: Line-upward the ii pins and the seal washer (gasket) with the corresponding holes on the cylinder mail valve�... -
Page xi: Operating Instructions
Assembly AND Apply OPERATING INSTRUCTIONS: STEP 1: Make certain that the BONSAI VELOCITY conserver is set to the ® "OFF" position before opening the cylinder valve� STEP ii: To reduce the take a chance of rapid oxygen recompression and fire, open the cylinder valve slowly and completely so the pressure gauge moves slowly as it indicates the cylinder pressure� Stride 3: Listen for leaks. If a leak is present, close the cylinder valve, cheque the CGA seal, and reinstall. If the leak persists, DO NOT Employ THE FIGURE K... -
Page 12: Oxygen Cylinder Elapsing
OXYGEN CYLINDER DURATION Because the total delivery of oxygen via the BONSAI VELOCITY conserver is related ® to breathing rates, it is user adaptive in that the total oxygen delivered per minute volition automatically suit with user need, equally expressed by increased or decreased breathing rates� For example, at all settings, twice equally much oxygen per minute will exist delivered if one breathes twenty (xx) times per minute equally compared with ten (10) times per minute�... -
Page 13: Care And Maintenance
CARE AND MAINTENANCE The BONSAI VELOCITY conserver is designed for a long and authentic life; however, ® equally with any pneumatic device, normal prudent care is required� The unit should be kept make clean and free from moisture and dust, as well as extreme temperature. Practise not betrayal the unit to water, such every bit when bathing or swimming. It is advisable to keep the arrangement in its conveying handbag to afford a degree of protection� Clean the outside of the unit of measurement periodically with a clean, lint-free cloth�... -
Folio fourteen: Products, Spare Parts, Accessories
PRODUCTS, SPARE PARTS, ACCESSORIES STANDARD PRODUCT Order NUMBER DESCRIPTION OM-812 BONSAI VELOCITY pneumatic oxygen conserving device with ® a gauge that reads up to 4,000 PSI SPARE PARTS ORDER NUMBER Clarification RP-3040 Black "south" cylinder adjustment knob FR-870G Viton seal washers (CGA 870 gaskets), bag of 10... -
Page 15: Troubleshooting
TROUBLESHOOTING Problem PROBABLE CAUSE SOLUTION Cylinder valve is closed� Turn the cylinder valve to the "ON" position� Cylinder is empty� Check the oxygen judge. Supersede the cylinder, if empty� Unit of measurement does not pulse� Oxygen cannula is blocked or Remove kinks. Clean or kinked. supersede, if necessary� Selector switch is set to the Make sure the selector switch is ready "OFF"... -
Page 16: Classifications
CLASSIFICATIONS The BONSAI VELOCITY conserver is classified every bit: ® • Course II, per FDA 21 CFR Role 868.5905 • Not suitable for use in the presence of flammable anesthetic mixture with air, oxygen, or nitrous oxide�... -
Folio 17: Specifications
SPECIFICATIONS Oxygen Delivery: SWITCH POSITION LITER Flow EQUIVALENCY cf ii cf iv Continuous Period Emergency Bypass Setting: Ii settings, factory preset at ii LPM and 4 LPM Regulator: Brass high-pressure level with aluminum low-pressure materials Dimensions: Approximately v�3" L (xiii�v cm) x 2�two" D (5�six cm) Weight: Approximately 10 ounces (283 grams) Operating Temperature:... -
Page 18: Limited Warranty
Express WARRANTY The BONSAI VELOCITY oxygen conserver has been carefully manufactured and ® inspected and is warranted to be free from defects in workmanship and materials. Nether this warranty, Chad Therapeutics' obligation shall exist limited to the replacement or repair of any such units or parts that evidence, by CHAD'south inspection, to exist defective within ii years from the date of buy�... -
Page 19: Of import Information To Record
IMPORTANT INFORMATION TO Tape Your Name: ______________________________________________________________ Date You Received Your Unit: ________________________________________________ Prescribed Oxygen Menstruum Setting: • At Residue: ___________________________ • During Exercise: ___________________________ Home Care Provider'south Proper name: _________________________________________________ Home Intendance Provider's Telephone Number: (________)________________________________ Physician's Name: __________________________________________________________ Physician's Phone Number: (_______)_________________________________________ Notes: ________________________________________________________________________ ________________________________________________________________________ ________________________________________________________________________... - Page 20 Manufactured by Inovo, Inc� 401 Leonard Blvd� Due north Lehigh Acres, FL 33971 Toll-free: 877-224-0946 Parent Company www�chadtherapeutics�com Drive Medical Design & Manufacturing 99 Seaview Boulevard United States Patent Number # 6,484,721 Port Washington, NY 11050 PM-00078/xiii/B Price-free: 877-224-0946 Printed in the U�S�A� www�drivemedical�com BONSAI and CHAD are registered trademarks of Inovo, Inc.